No. de Modèle
|
|
KSG-10K
|
KSG-15K
|
KSG-20K
|
KSG-30K
|
KSG-50K
|
KSG-60K
|
|
|
|
|
Puissance DC Maximum
|
|
11,5 kW
|
16,5 kW
|
22,5 kW
|
39 kW
|
65 kW
|
78 kW
|
|
|
Tension DC maximum
|
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
|
|
Tension DC Nominal
|
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
|
|
Tension DC minimum
|
|
250 V
|
250 V
|
250 V
|
250 V
|
250 V
|
250 V
|
|
|
Courant DC maximum
|
|
26 A
|
42 A
|
42 A
|
42 A
|
108 A
|
120 A
|
|
|
Plage de Tension MPP(T)
|
|
250~950 V
|
250~950 V
|
250~950 V
|
250~950 V
|
250~950 V
|
250~950 V
|
|
|
Nombre de MPPT
|
|
|
Sortie DC
|
|
|
|
|
Puissance AC Maximum
|
|
11 kW
|
16 kW
|
22 kW
|
33 kW
|
55 kW
|
66 kW
|
|
|
Puissance AC nominal
|
|
10 kW
|
15 kW
|
20 kW
|
30 kW
|
50 kW
|
60 kW
|
|
|
Plage de Tension AC Sortie
|
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
|
|
Tension AC nominal
|
|
400 V
|
400 V
|
400 V
|
400 V
|
400 V
|
400 V
|
|
|
Courant AC maximum
|
|
17 A
|
24 A
|
32 A
|
48 A
|
80 A
|
95 A
|
|
|
Plage de fréquence
|
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
|
|
Fréquence
|
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
|
Taux de distorsion harmonique (THD)
|
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
|
Nombres de phases d'alimentation
|
|
|
Efficacité maximum
|
|
98 %
|
98 %
|
98 %
|
98,3 %
|
98,6 %
|
98,6 %
|
|
|
Efficacité européene
|
|
97,5 %
|
97,5 %
|
97,5 %
|
98 %
|
98,2 %
|
98,2 %
|
|
|
|
|
Dimensions (H/L/P)
|
|
715x553x228 mm
|
715x553x228 mm
|
715x553x228 mm
|
958x636x260 mm
|
958x636x260 mm
|
958x636x260 mm
|
|
|
Poids
|
|
35 kg
|
39 kg
|
39 kg
|
61 kg
|
68 kg
|
70 kg
|
|
|
Niveau de bruit
|
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 60 dB(A)
|
< 60 dB(A)
|
|
|
Température d'utilisation
|
-25 ~ +60 ℃
|
|
Transformateur
|
Sans Transformateur
|
|
Classe de Protection
|
IP65
|
|
Refroidissement
|
Naturel, Ventilateur
|
|
Interface
|
RS 485, WLAN
|
|
Exposition
|
LCD
|
|
|
|
Caractéristiques de Protection
|
Îlot de Protection, Protection Surtention, Protection contre l'inversion des Polarités, Surveillance des Défauts à la Terre
|