No. de Modèle
|
R5515TL
|
R6615TL
|
R7715TL
|
R8815TL
|
R10015TL
|
R11015TL
|
|
Entrée (DC)
|
|
Tension DC maximum
|
1500 V
|
1500 V
|
1500 V
|
1500 V
|
1500 V
|
1500 V
|
|
Courant DC maximum
|
800 A
|
960 A
|
1120 A
|
1280 A
|
1440 A
|
1600 A
|
|
Plage de Tension MPP(T)
|
675~1320 V
|
675~1320 V
|
675~1320 V
|
675~1320 V
|
675~1320 V
|
675~1320 V
|
|
Nombre de Branche MPPT
|
|
Sortie DC
|
|
Sortie (AC)
|
|
Puissance AC Maximum
|
513 kW
|
615 kW
|
718 kW
|
820 kW
|
923 kW
|
1025 kW
|
|
Puissance AC nominal
|
513 kW
|
615 kW
|
718 kW
|
820 kW
|
923 kW
|
1025 kW
|
|
Plage de Tension AC Sortie
|
360~440 V
|
360~440 V
|
360~440 V
|
360~440 V
|
360~440 V
|
360~440 V
|
|
Courant AC maximum
|
741 A
|
889 A
|
1037 A
|
1185 A
|
1333 A
|
1480 A
|
|
Plage de fréquence
|
50-60 Hz
|
50-60 Hz
|
50-60 Hz
|
50-60 Hz
|
50-60 Hz
|
50-60 Hz
|
|
Fréquence
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
Taux de distorsion harmonique (THD)
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
Nombres de phases d'alimentation
|
|
Efficacité maximum
|
98,8 %
|
98,8 %
|
98,8 %
|
98,8 %
|
98,9 %
|
98,9 %
|
|
Efficacité européene
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,62 %
|
98,62 %
|
|
Données Générales
|
|
Dimensions (H/L/P)
|
2235x1400x825 mm
|
2235x1996x825 mm
|
2235x1996x825 mm
|
2235x1996x825 mm
|
2235x1996x825 mm
|
2235x1996x825 mm
|
|
Poids
|
1300 kg
|
1320 kg
|
1400 kg
|
1430 kg
|
1500 kg
|
1530 kg
|
|
Consommation propre durant la nuit
|
< 60 W
|
< 60 W
|
< 60 W
|
< 60 W
|
< 60 W
|
< 60 W
|
|
Niveau de bruit
|
< 70 dB(A)
|
< 70 dB(A)
|
< 70 dB(A)
|
< 70 dB(A)
|
< 70 dB(A)
|
< 70 dB(A)
|
|
Température d'utilisation
|
-10 ~ +50 ℃
|
Transformateur
|
Sans Transformateur
|
Classe de Protection
|
IP20
|
Humidité
|
0-95 %
|
Refroidissement
|
Ventilateur
|
Altitude maximum
|
1000 m
|
PDF
|
|
Télécharger le PDF du Fabricant
|
|